Deskripsi Produk Flow Meter Aqua Metro CONTOIL VZO 15 – VZO 50
Aqua Metro CONTOIL VZO 15 – VZO 50 Mechanical Oil Flow Meters, PN25 Or PN40 Flanged
Oil meters with mechanical roller counter, and with DIN 2501 (As Standard) flanged connections.
American ANSI 150 and Japanese JIS 10-20K flange drillings are available at no extra cost, these are not added to the part number charts below because they have no factory defined part numbers, however for weights and dimensions, please use standard DIN 2501 listed specifications.
Not approved for resale use
Reed switch RV or inductive pulser IN (NAMUR IEC 60947-5-6) are also available. Please email for prices and datasheet if required
Suitable for Fuel Types;
- Heating Fuel, Extra Light / Light / Medium / Heavy (DN20 or above)
- Kerosene
- Naphtha
- Diesel
- Petrol
- Lubricating Oils
Your Benefits
- High operational safety due to vibration resistance
- Space saving installation without requirement of straight inlet and outlet paths
- Easy to install without restriction either horizontally, vertically or inclined
- High operational safety due to integral safety filter in the meter inlet. Reduces effort on start-up
VZO 15 | VZO 20 | VZO 25 | VZO 40 | VZO 50 | |
Nominal Diameter | 15 mm / 1/2″ | 20 mm / 3/4″ | 25 mm / 1″ | 40 mm / 1.5″ | 50 mm / 2″ |
Installation Length | 165 mm | 165 mm | 190 mm | 300 mm | 350 mm |
Connection Threads | None, DIN 2501 Flanged | None, DIN 2501 Flanged | None, DIN 2501 Flanged | None, DIN 2501 Flanged | None, DIN 2501 Flanged |
Nominal Pressure – Threaded | 16 Bar | 16 Bar | 16 Bar | 16 Bar | 16 Bar |
Nominal Pressure – Flanged | 25 Bar Or 40 Bar | 25 Bar Or 40 Bar | 25 Bar Or 40 Bar | 25 Bar Or 40 Bar | 25 Bar Or 40 Bar |
Maximum Temperature | +130 or +180 Celcius | +130 or +180 Celcius | +130 or +180 Celcius | +130 or +180 Celcius | +130 or +180 Celcius |
Maximum Flow Rate | 600 lph | 1,500 lph | 3,000 lph | 9,000 lph | 30,000 lph |
Continuous Flow Rate | 400 lph | 1,000 lph | 2,000 lph | 6,000 lph | 20,000 lph |
Minimum Flow Rate | 10 lph | 30 lph | 75 lph | 225 lph | 750 lph |
Approx Starting Flowrate | 4 lph | 12 lph | 30 lph | 90 lph | 300 lph |
Maximum Permissible Error | ±1.0% of reading | ±1.0% of reading | ±1.0% of reading | ±1.0% of reading | ±1.0% of reading |
Smallest Readable Amount | 0.01 Litres | 0.1 Litres | 0.1 Litres | 0.1 Litres | 1 Litre |
Registration Capacity | 1,000 Litres | 10,000 Litres | 10,000 Litres | 10,000 Litres | 100,000 Litres |
Safety Filter Mesh Size | 400 Micron | 400 Micron | 400 Micron | 800 Micron | 800 Micron |
Dirt Filter Mesh Size | 250 Micron | 400 Micron | 400 Micron | 600 Micron | 600 Micron |
Volume of Measuring Chamber | 12 cm3 | 36 cm3 | 100 cm3 | 330 cm3 | 1,200 cm3 |
Ingress Protection | IP65 | IP65 | IP65 | IP65 | IP65 |
VZO 15 | VZO 20 | VZO 25 | VZO 40 | VZO 50 | |
Length | 165 mm | 165 mm | 190 mm | 300 mm | 350 mm |
Width | 105 mm | 105 mm | 130 mm | 210 mm | 280 mm |
Height 130c Type | 106 mm | 115 mm | 142 mm | 235 mm | 291 mm |
Height 180c Type | 147 mm | 156 mm | 183 mm | 235 mm | 291 mm |
Weight – PN25 Flanged | 3.8 kg | 4.5 kg | 7.5 kg | 20.3 kg | 41.0 kg |
Weight – PN40 Flanged | 4.4 kg | 5.5 kg | 7.8 kg | 20.5 kg | 42.0 kg |
Display | Temp Max | Pressure Max | Pulser Type | Litres Per Pulse | Pulses Per Litre | Part Number DN15 | Part Number DN20 | Part Number DN25 | Part Number DN40 | Part Number DN50 |
Local | 130 Celcius | 25 Bar | – | – | – | VZO 15 FL 130/25 | VZO 20 FL 130/25 | VZO 25 FL 130/25 | VZO 40 FL 130/25 | VZO 50 FL 130/25 |
Local | 130 Celcius | 25 Bar | Reed Switch | 0.1 | 10 | VZO 15 FL 130/25-RV 0.1 | – | – | – | – |
Local | 130 Celcius | 25 Bar | Reed Switch | 1 | 1 | VZO 15 FL 130/25-RV 1 | VZO 20 FL 130/25-RV 1 | VZO 25 FL 130/25-RV 1 | VZO 40 FL 130/25-RV 1 | – |
Local | 130 Celcius | 25 Bar | Reed Switch | 10 | – | – | – | VZO 40 FL 130/25-RV 10 | VZO 50 FL 130/25-RV 10 | |
Local | 130 Celcius | 25 Bar | Reed Switch | 100 | – | – | – | – | VZO 50 FL 130/25-RV 100 | |
Local | 130 Celcius | 25 Bar | Inductive Pulser | 0.01 | 100 | VZO 15 FL 130/25-IN 0.01 | VZO 20 FL 130/25-IN 0.01 | – | – | – |
Local | 130 Celcius | 25 Bar | Inductive Pulser | 0.1 | 10 | – | – | VZO 25 FL 130/25-IN 0.1 | VZO 40 FL 130/25-IN 0.1 | – |
Local | 130 Celcius | 25 Bar | Inductive Pulser | 1 | 1 | – | – | – | – | VZO 50 FL 130/25-IN 1 |
Local | 180 Celcius | 25 Bar | – | – | – | VZO 15 FL 180/25 | VZO 20 FL 180/25 | VZO 25 FL 180/25 | VZO 40 FL 180/25 | VZO 50 FL 180/25 |
Local | 180 Celcius | 25 Bar | Reed Switch | 0.1 | 10 | VZO 15 FL 180/25-RV 0.1 | – | – | – | – |
Local | 180 Celcius | 25 Bar | Reed Switch | 1 | 1 | VZO 15 FL 180/25-RV 1 | VZO 20 FL 180/25-RV 1 | VZO 25 FL 180/25-RV 1 | VZO 40 FL 180/25-RV 1 | – |
Local | 180 Celcius | 25 Bar | Reed Switch | 10 | – | – | – | – | VZO 50 FL 180/25-RV 10 | |
Local | 180 Celcius | 25 Bar | Inductive Pulser | 0.01 | 100 | VZO 15 FL 180/25-IN 0.01 | VZO 20 FL 180/25-IN 0.01 | – | – | |
Local | 180 Celcius | 25 Bar | Inductive Pulser | 0.1 | 10 | – | – | VZO 25 FL 180/25-IN 0.1 | VZO 40 FL 180/25-IN 0.1 | |
Local | 180 Celcius | 25 Bar | Inductive Pulser | 1 | 1 | – | – | – | – | VZO 50 FL 180/40-IN 1 |
Local | 180 Celcius | 40 Bar | – | – | – | VZO 15 FL 180/40 | VZO 20 FL 180/40 | VZO 25 FL 180/40 | VZO 40 FL 180/40 | VZO 50 FL 180/40 |
Local | 180 Celcius | 40 Bar | Reed Switch | 0.1 | 10 | VZO 15 FL 180/40-RV 0.1 | – | – | – | – |
Local | 180 Celcius | 40 Bar | Reed Switch | 1 | 1 | VZO 15 FL 180/40-RV 1 | VZO 20 FL 180/40-RV 1 | VZO 25 FL 180/40-RV 1 | VZO 40 FL 180/40-RV 1 | – |
Local | 180 Celcius | 40 Bar | Reed Switch | 10 | – | – | – | – | VZO 50 FL 180/40-RV 10 | |
Local | 180 Celcius | 40 Bar | Inductive Pulser | 0.01 | 100 | VZO 15 FL 180/40-IN 0.01 | VZO 20 FL 180/40-IN 0.01 | – | – | |
Local | 180 Celcius | 40 Bar | Inductive Pulser | 0.1 | 10 | – | – | VZO 25 FL 180/40-IN 0.1 | VZO 40 FL 180/40-IN 0.1 | |
Local | 180 Celcius | 40 Bar | Inductive Pulser | 1 | 1 | – | – | – | – | VZO 50 FL 180/40-IN 1 |
Display | Temp Max | Pressure Max | Pulser Type | Litres Per Pulse | Pulses Per Litre | Part Number DN15 | Part Number DN20 | Part Number DN25 | Part Number DN40 | Part Number DN50 |
Local | 130 Celcius | 25 Bar | – | – | – | 92044 | 92049 | 92059 | 92005 | 92007 |
Local | 130 Celcius | 25 Bar | Reed Switch | 0.1 | 10 | 92045 | – | – | – | – |
Local | 130 Celcius | 25 Bar | Reed Switch | 1 | 1 | 92046 | 92050 | 92060 | 92020 | – |
Local | 130 Celcius | 25 Bar | Reed Switch | 10 | – | – | – | 92021 | 92024 | |
Local | 130 Celcius | 25 Bar | Reed Switch | 100 | – | – | – | – | 92025 | |
Local | 130 Celcius | 25 Bar | Inductive Pulser | 0.01 | 100 | 91910 | 91903 | – | – | – |
Local | 130 Celcius | 25 Bar | Inductive Pulser | 0.1 | 10 | – | – | 91914 | 91907 | – |
Local | 130 Celcius | 25 Bar | Inductive Pulser | 1 | 1 | – | – | – | – | 91909 |
Local | 180 Celcius | 25 Bar | – | – | – | 92250 | 92258 | 92264 | 92274 | 92280 |
Local | 180 Celcius | 25 Bar | Reed Switch | 0.1 | 10 | 92251 | – | – | – | – |
Local | 180 Celcius | 25 Bar | Reed Switch | 1 | 1 | 92252 | 92259 | 92265 | 92275 | – |
Local | 180 Celcius | 25 Bar | Reed Switch | 10 | – | – | – | – | 92281 | |
Local | 180 Celcius | 25 Bar | Inductive Pulser | 0.01 | 100 | 92253 | 92260 | – | – | |
Local | 180 Celcius | 25 Bar | Inductive Pulser | 0.1 | 10 | – | – | 92266 | 92276 | |
Local | 180 Celcius | 25 Bar | Inductive Pulser | 1 | 1 | – | – | – | – | 92282 |
Local | 180 Celcius | 40 Bar | – | – | – | 92254 | 92261 | 92267 | 92277 | 92283 |
Local | 180 Celcius | 40 Bar | Reed Switch | 0.1 | 10 | 92255 | – | – | – | – |
Local | 180 Celcius | 40 Bar | Reed Switch | 1 | 1 | 92256 | 92262 | 92268 | 92278 | – |
Local | 180 Celcius | 40 Bar | Reed Switch | 10 | – | – | – | – | 92284 | |
Local | 180 Celcius | 40 Bar | Inductive Pulser | 0.01 | 100 | 92257 | 92263 | – | – | |
Local | 180 Celcius | 40 Bar | Inductive Pulser | 0.1 | 10 | – | – | 92269 | 92279 | |
Local | 180 Celcius | 40 Bar | Inductive Pulser | 1 | 1 | – | – | – | – | 92285 |